Product Test Report: Diaphragm
Certified third-party test lab Terrapin Testing, Inc. (IAS Testing Laboratory TL-159 and Florida Accreditation Laboratory TST2542) has conducted a series of tests on Veristeel's VeriClad
® composite structural panels in accordance with ICC Evaluation Service Acceptance Criteria for Sandwich Panels AC04.
If you are a dealer, manufacturer or code official, please
click here to request a copy of relevant third-party test reports or call us at (702) 459-5005.
| Tests Conducted |
Test Type & Results
|
Links
|
|
VeriClad® Foam Core Panels
|
| Diaphragm |
Based on test data provided by Terrapin Testing (IAS TL-159, FLA TST2542), TJC & Associates has determined that the allowable diaphragm shear load for the VeriClad® panels is 250 pounds per lineal foot. When subjected to the allowable shear load, a diaphragm with a 2-to-1 aspect ratio can be expected to deflect less than 0.1 inches. |