Product Test Report: Diaphragm

Certified third-party test lab Terrapin Testing, Inc. (IAS Testing Laboratory TL-159 and Florida Accreditation Laboratory TST2542) has conducted a series of tests on Veristeel's VeriClad® composite structural panels in accordance with ICC Evaluation Service Acceptance Criteria for Sandwich Panels AC04.

If you are a dealer, manufacturer or code official, please click here to request a copy of relevant third-party test reports or call us at (702) 459-5005.


Tests Conducted

Test Type & Results

Links


VeriClad® Foam Core Panels

Diaphragm Based on test data provided by Terrapin Testing (IAS TL-159, FLA TST2542), TJC & Associates has determined that the allowable diaphragm shear load for the VeriClad® panels is 250 pounds per lineal foot.  When subjected to the allowable shear load, a diaphragm with a 2-to-1 aspect ratio can be expected to deflect less than 0.1 inches.