| Tests Conducted |
Test Type & Results
|
Links |
Links |
|
VeriClad® Foam Core Panels
|
|
ASTM E 72-98 |
Transverse load testing in accordance with ICC-ES Acceptance Criteria for Sandwich Panels (AC04) Section 4.6; results incorporated into certified panel span tables |
View SpanTable |
Request Report |
|
ASTM E 661-88 |
Concentrated load tests in accordance with ICC-ES AC04 Section 4.6.2; results incorporated into certified panel span tables |
View SpanTable |
Request Report |
|
ASTM Std. E8 |
Coupon tests in accordance with ICC-ES AC04 Section 2.2; results incorporated into certified panel span tables |
View SpanTable |
Request Report |
|
ASTM Std. C271-61 |
Core density tests in accordance with ICC-ES AC04 Section 4.8; results incorporated into certified panel span tables |
View SpanTable |
Request Report |
|
Uplift & Shear |
Uplift and shear connection tests in accordance with ICC-ES AC04 Section 4.2.7 |
View SpanTable |
Request Report |
| Diaphragm |
Based on test data provided by Terrapin Testing (IAS TL-159, FLA TST2542), TJC & Associates has determined that the allowable diaphragm shear load for the VeriClad® panels is 250 pounds per lineal foot. When subjected to the allowable shear load, a diaphragm with a 2-to-1 aspect ratio can be expected to deflect less than 0.1 inches. |
|
Request Report |
| ASTM E-84 |
Flame spread & smoke development test; the VeriClad® foam core panels are recognized as Class A (IBC), Class 1 (UBC), and they comply with IRC under Section R315. |
|
Request Report |
| NFPA 286 |
Full-scale room corner fire test of roof/ceiling assembly; the VeriClad® foam core panels demonstrated acceptable fire performance with the use of a 15-minute thermal barrier (i.e., gyp board). |
|
Request Report |
| UL 1715 |
Full-scale fire test of floor assembly; the VeriClad™ foam core panels demonstrated acceptable fire performance with the use of a 1/4" reinforced mineral board. |
|
Request Report |
| ICC-ES Acceptance Criteria AC04 |
Third Party Tests for Structural Composite Floor and Roof Panels to confirm comprehensive compliance with ICC-ES Acceptance Criteria for Sandwich Panels AC04, conducted by Terrapin Testing (IAS TL-159, FLA TST2542), Report No. TT506001F |
|
Request Report |
|
VeriClad® Honeycomb Core Panels
|
| ASTM E 72-98 |
Transverse load testing in accordance with ICC-ES Acceptance Criteria for Sandwich Panels (AC04) Section 4.6; results incorporated into certified panel span tables |
View SpanTable |
Request Report |
| ASTM E 661-88 |
Concentrated load tests in accordance with ICC-ES AC04 Section 4.6.2; results incorporated into certified panel span tables |
View SpanTable |
Request Report |
| ASTM Std. E8 |
Coupon tests in accordance with ICC-ES AC04 Section 2.2; results incorporated into certified panel span tables |
View SpanTable |
Request Report |
| Uplift & Shear |
Uplift and shear connection tests in accordance with ICC-ES AC04 Section 4.2.7 |
|
Request Report |
| Diaphragm |
Based on test data provided by Terrapin Testing (IAS TL-159, FLA TST2542), TJC & Associates has determined that the allowable diaphragm shear load for the VeriClad® panels is 250 pounds per lineal foot. When subjected to the allowable shear load, a diaphragm with a 2-to-1 aspect ratio can be expected to deflect less than 0.1 inches. |
|
Request Report |
| ASTM E-84 |
Flame spread & smoke development test; the VeriClad® honeycomb core panels are recognized as Class A (IBC), Class 1 (UBC), and they comply with IRC under Section R315. |
|
Request Report |
| ICC-ES Acceptance Criteria AC04 |
Third Party Tests for Structural Composite Floor and Roof Panels to confirm comprehensive compliance with ICC-ES Acceptance Criteria for Sandwich Panels AC04, conducted by Terrapin Testing (IAS TL-159, FLA TST2542), Report No. TT506001A |
|
Request Report |