Certified third-party test lab Terrapin Testing, Inc. (IAS Testing Laboratory TL-159 and Florida Accreditation Laboratory TST2542) has conducted a series of tests on Veristeel's VeriClad® composite structural panels in accordance with ICC Evaluation Service Acceptance Criteria for Sandwich Panels AC04.

If you are a dealer, manufacturer or code official, please click here to request a copy of relevant third-party test reports or call us at (702) 459-5005.






Tests Conducted

Test Type & Results

 Links

Links


VeriClad® Foam Core Panels

ASTM E 72-98

Transverse load testing in accordance with ICC-ES Acceptance Criteria for Sandwich Panels (AC04) Section 4.6; results incorporated into certified panel span tables

View SpanTable

Request
Report

ASTM E 661-88 

Concentrated load tests in accordance with ICC-ES AC04 Section 4.6.2; results incorporated into certified panel span tables

View SpanTable

Request
Report

ASTM Std. E8 

Coupon tests in accordance with ICC-ES AC04 Section 2.2; results incorporated into certified panel span tables

View SpanTable

Request
Report

ASTM Std. C271-61

Core density tests in accordance with ICC-ES AC04 Section 4.8; results incorporated into certified panel span tables

View SpanTable

Request
Report

Uplift & Shear

Uplift and shear connection tests in accordance with ICC-ES AC04 Section 4.2.7

View SpanTable

Request
Report

Diaphragm Based on test data provided by Terrapin Testing (IAS TL-159, FLA TST2542), TJC & Associates has determined that the allowable diaphragm shear load for the VeriClad® panels is 250 pounds per lineal foot.  When subjected to the allowable shear load, a diaphragm with a 2-to-1 aspect ratio can be expected to deflect less than 0.1 inches.

Request
Report

ASTM E-84 Flame spread & smoke development test; the VeriClad® foam core panels are recognized as Class A (IBC), Class 1 (UBC), and they comply with IRC under Section R315.

Request
Report

NFPA 286 Full-scale room corner fire test of roof/ceiling assembly; the VeriClad® foam core panels demonstrated acceptable fire performance with the use of a 15-minute thermal barrier (i.e., gyp board).

Request
Report

UL 1715 Full-scale fire test of floor assembly; the VeriClad™ foam core panels demonstrated acceptable fire performance with the use of a 1/4" reinforced mineral board.

Request
Report

ICC-ES Acceptance Criteria AC04 Third Party Tests for Structural Composite Floor and Roof Panels to confirm comprehensive compliance with ICC-ES Acceptance Criteria for Sandwich Panels AC04, conducted by Terrapin Testing (IAS TL-159, FLA TST2542), Report No. TT506001F

Request
Report

NEW!
ICC-ES-2212

DIVISION: 07—THERMAL AND MOISTURE PROTECTION
Section: 07410—Metal Roof and Wall Panels

Request
Report


VeriClad® Honeycomb Core Panels

ASTM E 72-98 Transverse load testing in accordance with ICC-ES Acceptance Criteria for Sandwich Panels (AC04) Section 4.6; results incorporated into certified panel span tables

View SpanTable

Request
Report

ASTM E 661-88 Concentrated load tests in accordance with ICC-ES AC04 Section 4.6.2; results incorporated into certified panel span tables

View SpanTable

Request
Report

ASTM Std. E8 Coupon tests in accordance with ICC-ES AC04 Section 2.2; results incorporated into certified panel span tables

View SpanTable

Request
Report

Uplift & Shear Uplift and shear connection tests in accordance with ICC-ES AC04 Section 4.2.7

Request
Report

Diaphragm Based on test data provided by Terrapin Testing (IAS TL-159, FLA TST2542), TJC & Associates has determined that the allowable diaphragm shear load for the VeriClad® panels is 250 pounds per lineal foot.  When subjected to the allowable shear load, a diaphragm with a 2-to-1 aspect ratio can be expected to deflect less than 0.1 inches.

Request
Report

ASTM E-84 Flame spread & smoke development test; the VeriClad® honeycomb core panels are recognized as Class A (IBC), Class 1 (UBC), and they comply with IRC under Section R315.

Request
Report

ICC-ES Acceptance Criteria AC04 Third Party Tests for Structural Composite Floor and Roof Panels to confirm comprehensive compliance with ICC-ES Acceptance Criteria for Sandwich Panels AC04, conducted by Terrapin Testing (IAS TL-159, FLA TST2542), Report No. TT506001A

Request
Report

 